Ultra Condensing Efficiency
Navienβs Condensing Technology offers the high efficiency.
Money and energy savings over tank type water heaters and traditional water heaters.
Two Stainless Steel Heat Exchangers
Provides longer life expectancy as they are highly resistant to corrosion and erosion compared to copper heat exchangers.
Reduces minerals deposits.
Low NOx Emissions (β€ 20ppm)
New metal fiber burner is designed to deliver a consistent air/gas mixture improving combustion efficiency.
Result in less acid rain and less green house effect.
Comply with SCAQMD 1146.2 strict NOx emissions standard.
2β PVC, CPVC, Polyprophylene Venting Up To 60β
2β venting option allows for a flue to be pulled through the existing vent.
3β vents can be used up to 150β with standard 2β x 3β adapters.
Utilizes Existing 1/2β³ Gas Line
The negative pressure gas valve and fan with dual venturi operation allows for better adaptability to low gas pressure applications.
Makes it possible for the NPE to be installed Β½β gas lines up to 24β.
Field Convertible
NPE models allow for easy convertibility from NG to LP.
Less Water Pressure Drop
Simple modular for water path minimizes water pressure drop.
Modular design for water path make maintenance easier and service can be performed easily in the field.
Intelligent Preheating Technology
Recognizes hot water usage patterns to intelligently provide hot water when needed.
Data Field | NPE-210A | |
Heat Capacity (Input) | Natural Gas | 19,900-180,000 BTU/H |
Propane Gas | 19,900-180,000 BTU/H | |
Energy Factor NG / LPG (DOE) | 0.97 / 0.97 | |
Flow Rate (DHW) | 35β°F(19β°C) Temp Rise | 10.1 GPM (38 L/m) |
45β°F(25β°C) Temp Rise | 7.8 GPM (30 L/m) | |
77β°F(43β°C) Temp Rise | 4.6 GPM (17 L/m) | |
Dimensions | 17.3β³(W) x 27.4β³(H) x 13.2β³(D) | |
Weight | 82 lbs (37 kg) | |
Installation Type | Indoor or Outdoor Wall-Hung | |
Venting Type | Forced Draft Direct Vent | |
Ignition | Electronic Ignition | |
Water Pressure | 15-150 PSI | |
Natural Gas Supply Pressure (from source) | 3.5β³-10.5β³ WC | |
Propane Gas Supply Pressure (from source) | 8β³-13β³ WC | |
Natural Gas Manifold Pressure (min to max) | -0.04β³ WC to -0.36β³ WC | |
Propane Gas Manifold Pressure(min to max) | -0.02β³ WC to -0.66β³ WC | |
Minimum Flow Rate | 0 GPM (0 L/m) | |
Connection Sizes | Cold Water Inlet | 3/4β³ NPT |
Hot Water Outlet | 3/4β³ NPT | |
Recirculation Inlet | 3/4β³ NPT | |
Gas Inlet | 3/4β³ NPT (Suitable for use with 1/2β³ rigid gas pipe; refer to installation manual for sizing criteria) |
|
Power Supply | Main Supply | 120 V AC, 60Hz |
Maximum Power Consumption | 200W (max 2A), 350W (max 4A) with external pump connected | |
Materials | Casing | Cold rolled carbon steel |
Heat Exchangers | Primary Heat Exchanger: Stainless Steel Secondary Heat Exchanger: Stainless Steel |
|
Venting | Exhaust | 2β³ or 3β³ PVC, CPVC, Polypropylene 2β³ or 3β³ Special Gas Vent Type BH (Class II, A/B/C) |
Intake | 2β³ or 3β³ PVC, CPVC, Polypropylene 2β³ or 3β³ Special Gas Vent Type BH (Class II, A/B/C) |
|
Vent Clearances | 0β³ to Combustibles | |
Safety Devices | APS, Ignition Operation Detector, Water Temperature High Limit Switch, Exhaust Temperature High Limit Sensor, Power Surge Fuse |